DONGGUAN YUYANG INSTRUMENT CO.,LTD
China Good Quality Manufacturer of Testing Equipment
Place of Origin: | China |
Brand Name: | YUYANG |
Certification: | GB/T 4508-2010, T0602-2011, JTG E20-2011, JTJ052, ASTM D113 |
Model Number: | YYL-018 |
Packaging Details: | Wooden Case |
---|---|
Delivery Time: | 5-8 work days |
Supply Ability: | 100 Piece/Pieces per Month |
Measurement Range:: | 2.0 M (±10mm) | Heating Type:: | By An Electric Heater |
---|---|---|---|
Heating Power:: | 3200 W | Temperature Controlling Range:: | 5~50°C; Digitally Displayed |
Temperature Controlling Accuracy:: | ±0.1°C | Dragging Speed:: | Two Grades, 10~50 Mm/min, |
Measurement Accuracy:: | ±1 Mm | Dragging Force Measurement Range:: | 0~300 N |
Dragging Force Accuracy:: | ±1N; | Display Resolution:: | 0.1 N |
Ambient Temperature:: | -10~+35°C | Relative Humidity:: | ≤85% |
High Light: | textile lab equipment,universal tensile machine |
10~50 mm/min Asphalt Ductility Tensile Testing Machine 0~300 N
Product Description:
Asphalt Ductility Tensile Testing Machine is suitable to determine the distance to which it will elongate before breaking when two ends of a briquet specimen of the material are pulled apart at a specified speed and at a specified temperature.
Main parameters:
Power supply: AC 220 V (-5%~+10%), 50 Hz
Measurement range: 2.0 m (±10mm)
Heating type: by an electric heater
Heating power: 3200 W
Bath circulation: by a magnetic circulation pump
Temperature controlling range: 5~50°C; digitally displayed
Temperature controlling accuracy: ±0.1°C
Dragging speed: two grades, 10~50 mm/min,
frequency conversion stepless adjustable
Measurement accuracy: ±1 mm
Ductility display: Controlled by microprocessor;
digitally displayed after data processing
Dragging force measurement range: 0~300 N
Dragging force accuracy: ±1N;
Display resolution: 0.1 N
Data output: 1) Communicate with a computer through a RS232 port
2) Printed out by a micro-printer
Refrigeration type: by a compressor; input power is 800 W
Ambient temperature: -10~+35°C
Relative humidity: ≤85%
Power supply | AC220V(-5%~+10%),50Hz |
Measurement range | 2.0m(±10mm) |
Heating mode | Electric heater |
Heating power | 3200W |
Liquid circulation | By magnet circulation pump |
Temperature control range | (5~50)°C,adjustable. Resolution is 0.01℃ |
Temperature control accuracy | ±0.1℃ |
Tensile speed | 10mm/min and 50mm/min, two grades |
Measurement accuracy | ±1 mm |
Ductility display | Digital display after data processed by a single chip machine |
Refrigeration | Compressor 1.25P, input power is 950W |
Ambient temperature | (-10~+35)℃ |
Relative humidity | ≤85% |
Maximum power consumption | 4100W |
Overall dimension | 2365mm×520mm×1000mm |
Standard:
GB/T 4508-2010, T0602-2011, JTG E20-2011, JTJ052, ASTM D113
Contact Person: Mele Pu
Tel: +8618476767313