Send Message
Tel:
DONGGUAN YUYANG INSTRUMENT CO., LTD
DONGGUAN YUYANG INSTRUMENT CO., LTD
Home ProductsEnvironmental Test Chamber

Stainless Steel Plate Environmental Test Chamber PID / SSR Control Thermal Shock Tester

Stainless Steel Plate Environmental Test Chamber PID / SSR Control Thermal Shock Tester

  • Stainless Steel Plate Environmental Test Chamber PID / SSR Control Thermal Shock Tester
  • Stainless Steel Plate Environmental Test Chamber PID / SSR Control Thermal Shock Tester
Stainless Steel Plate Environmental Test Chamber PID / SSR Control Thermal Shock Tester
Product Details:
Place of Origin: China
Brand Name: YUYANG
Certification: CE, UL, ISO
Model Number: YY1016
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: Negotiation
Packaging Details: Plywood Case
Delivery Time: 15-20 work days
Payment Terms: T/T, L/C, Western Union
Supply Ability: 2 sets per month
Contact Now
Detailed Product Description
Product Name: Environmental Test Chamber Usage: Thermal Shock Testing Chamber
Material: Stainless Steel Plate Internal Dimension: 40×36×35 Cm
Cooling Method: Water Power Supply: AC380V, 50/60HZ
Temperature Uniformity: ±2.00°C Simulated Load: 5.0kg
Preheating Time: 30MIN Precooling Time: 60MIN
High Light:

thermal shock test chamber

,

salt spray test chamber

 

 

Environmental Test Chamber , PID / SSR Control Method Thermal Shock Testing Chamber

 

 

Description:

 

PID and SSR Control Method Thermal Shock Testing Chamber is used to test the bearing extent of the material structures and composite material in an instant and continuous high temperature and extremely low temperature environment , that is in the shortest time to test its thermal expansion and contraction caused by chemical change or physical harm. Application objects, including metal, plastic, rubber, electronics ... and other materials can be used as a basis to improve their products or reference.

 

 

Features:

 

1. PID and SSR Control Method Thermal Shock Testing Chamber

2. Micro processor, multi function control. To control and monitor the compressor, the solenoid valve and the heater .

3. When faults occur, the auto detection and protection function will activate and will automatically cut off the power, the LCD screen will shows the fault status.

4. Appointment function , the equipment can be activate and start for operation through setting (Year, month, date, hour and minute)

5. Accumulation operation time provide a record for management and maintanence.

6. Setting of the backlite of the LCD can extend the useful life of the LCD.

7. Can choose one paragraph of control or the multi-screen process to increase the convenience of its operation.

8. Curve drawing function: After setting up the operation parameters or during the running mode, you can call out the screen to understand the running situations and conditions.

9. Program execution can be suspended (HOLD), Jump paragraph (ADV) and other procedures involved in setting.

10. Recovery time and test time WAIT function.

11. Power breakdown recovery function, can select BREAK, COLD, or HOT.

 

 

Specification:

 

Model PID and SSR Control Method Thermal Shock Testing Chamber
Internal Dimension: (W×H×D)40×36×35 cm
Structure: Two chambers design(the hot chamber or the cold chamber)
Damper device: Forced air drived damper
Interior material: SUS# Stainless steel plate
Exterior material: SUS# Stainless steel plate
Basket material: SUS# Stainless steel plate
Refrigeration: Cascade refrigeration system
Cooling method: Water
Ambient temperature: 0°~30°
Preheating temperature: above freezing 60.00°C~above freezing200.00°C
Precooling temperature: subzero 10.00°~ subzero 70.00°C
H.T. Shocking: above freezing 60.00°C~above freezing 150.00°C
L.T. Shocking: subzero 10.00°C~subzero 65.00°C
Temperature uniformity: ±2.00°C
Simulated load ic 5.0kg
HT IN-Zone subzero 65.00°C~above freezing 150.00°C/5min
LT IN-Zone above freezing 150.00°C subzero 65.00°C
Preheating time: 30MIN
Precooling time: 60MIN
Senor: T×4
Controller: OYO-8226
Setting range: Temperature:subzero 100.00°C~above freezing 200.00°C/TIME:OHIM~999H/CYCLE:0 ~9999
Resolution: Temperature:0.1°C
Output mode: PID and SSR(control method)
Power(K.W) AC380V 50HZ 18KW

 

 

(thermal shock chamber) Related Products:
Model / Link Interior Dimensions(W x D x H) Temperature Range Notes
YY1016-18 320x230x250mm -50℃-175℃ Within 5 minutes / 2 working chambers
YY1016-100 500*450*450mm -40 ~ +80℃ Within 5 minutes / 3 working chambers

 

Stainless Steel Plate Environmental Test Chamber PID / SSR Control Thermal Shock Tester 0

 

 

Contact Details
DONGGUAN YUYANG INSTRUMENT CO., LTD

Contact Person: Seline Yu

Tel: +86-13825728643

Send your inquiry directly to us
DONGGUAN YUYANG INSTRUMENT CO., LTD
B1505, FORTUNE PLAZA, No.1, Yuanmei Road, Nancheng District, Dongguan City, Guangdong Province, China
Tel:86-769-26622869
Mobile Site Privacy Policy | China Good Quality Flammability Testing Equipment Supplier. © 2017 - 2024 flammabilitytestingequipment.com. All Rights Reserved.