Product Details:
Place of Origin: China
Brand Name: YUYANG
Certification: EN 136 ,GB 19083-2010 ,YY 0469-2011,GB 2626-2006
Model Number: YYF089
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Plywood box
Delivery Time: 8-10 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union,
Supply Ability: 300/sets/Month
Contact Now
Detailed Product Description
Linear Velocity Of Head Automatic Movement: (60±5)mm/s Flame Height: 40±4mm
Flame Temperature Measurement: Thermocouple Detection Burner Height Adjustment Range: 30mm
Combustion Timer: 0~9999.9s Accuracy: ±0.1s
High Light:

flame test equipment

,

flammability test apparatus

GB 19083 Medical Surgical Mask Flame Retardant Tester (60±5)mm/s

 

Brief Introduction:

Medical Face Mask Fire Resistance Tester is mainly used to test the flame retardant performance of medical masks. The combustion performance of the mask is measured through a head mold wearing a mask de-vice to contact with the flame at a certain linear speed.

 

The device is mainly used in the field of medical protection, and also can also be used for
testing flame retardant properties of other textile coating materials.

 

Standard

GB 19083-2010 Technical requirements of
medical protective masks
YY 0469-2011 Technical requirements of
medical surgical masks-Blood penetration
test device
GB 2626-2006 Respiratory protective products, Self - priming filtering particulates respirator-flammability
BS EN136-1998 Respiratory protective de-
vices -Full face masks - Requirements testing, marking

 

Parameters:

 

Items Parameters
Linear velocity of head automatic movement (60±5)mm/s
Flame height 40±4mm
Flame temperature measurement Thermocouple detection
Burner height adjustment range 30mm
Metal head mold surface thickness 2~3mm,Resistance to flame combustion
Combustion timer 0~9999.9s
Accuracy ±0.1s
Power supply AC220V,50Hz,500W
Weight About 30kg
When the flame is (20±2)mm above the burner, the temperature is (800±50)℃.  
distance between the top of the burner and mask lowest point is(20±2)mm.  

 Medical Surgical Mask Flame Retardant Testing Machine (60±5)mm/s GB19083 0Medical Surgical Mask Flame Retardant Testing Machine (60±5)mm/s GB19083 1

Contact Details
DONGGUAN YUYANG INSTRUMENT CO., LTD

Contact Person: Yannis Ye

Tel: +86-13825723571

Send your inquiry directly to us
DONGGUAN YUYANG INSTRUMENT CO., LTD
B1505, FORTUNE PLAZA, No.1, Yuanmei Road, Nancheng District, Dongguan City, Guangdong Province, China
Tel:86-769-26622869
Mobile Site Privacy Policy | China Good Quality Flammability Testing Equipment Supplier. © 2017 - 2024 flammabilitytestingequipment.com. All Rights Reserved.