Linear Velocity Of Head Automatic Movement:
(60±5)mm/s
Flame Height:
40±4mm
Flame Temperature Measurement:
Thermocouple Detection
Burner Height Adjustment Range:
30mm
Combustion Timer:
0~9999.9s
Accuracy:
±0.1s
Highlight:

flame test equipment

,

flammability test apparatus

Payment & Shipping Terms
Minimum Order Quantity
1
Packaging Details
Plywood box
Delivery Time
8-10 days
Payment Terms
L/C, D/A, D/P, T/T, Western Union,
Supply Ability
300/sets/Month
Product Description

GB 19083 Medical Surgical Mask Flame Retardant Tester (60±5)mm/s

 

Brief Introduction:

Medical Face Mask Fire Resistance Tester is mainly used to test the flame retardant performance of medical masks. The combustion performance of the mask is measured through a head mold wearing a mask de-vice to contact with the flame at a certain linear speed.

 

The device is mainly used in the field of medical protection, and also can also be used for
testing flame retardant properties of other textile coating materials.

 

Standard

GB 19083-2010 Technical requirements of
medical protective masks
YY 0469-2011 Technical requirements of
medical surgical masks-Blood penetration
test device
GB 2626-2006 Respiratory protective products, Self - priming filtering particulates respirator-flammability
BS EN136-1998 Respiratory protective de-
vices -Full face masks - Requirements testing, marking

 

Parameters:

 

Items Parameters
Linear velocity of head automatic movement (60±5)mm/s
Flame height 40±4mm
Flame temperature measurement Thermocouple detection
Burner height adjustment range 30mm
Metal head mold surface thickness 2~3mm,Resistance to flame combustion
Combustion timer 0~9999.9s
Accuracy ±0.1s
Power supply AC220V,50Hz,500W
Weight About 30kg
When the flame is (20±2)mm above the burner, the temperature is (800±50)℃.  