ISO9239 Compliant Critical Radiant Flux Tester with 2KW Total Power and 300mm × 450mm Radiant Panel for Flooring Heat Flux Testing

ISO9239 Compliant Critical Radiant Flux Tester with 2KW Total Power and 300mm × 450mm Radiant Panel for Flooring Heat Flux Testing

ISO9239 Compliant Radiant Heat Flux Test Apparatus

2KW Total Power Critical Radiant Flux Tester

300mm × 450mm Radiant Panel Flooring Radiant Heat Flux Tester

Place of Origin:

China

Brand Name:

YUYANG

Certification:

ISO

Model Number:

YYF001

Contact Us
Request A Quote
Product Details
Exhaust Speed:
(2.5 ± 0.2) M/s
Thermocouple Type:
K-type Stainless Steel Sheathed Thermocouple, Diameter 3.2mm
Total Power:
2KW
Heat Flux Accuracy:
< ±3%
Thermal Radiation Range:
400–600 ℃, Accuracy ±0.5 ℃
Radiant Panel Size:
300mm × 450mm, Approx. 900 ℃ High Temperature Capability
Highlight:

ISO9239 Compliant Radiant Heat Flux Test Apparatus

,

2KW Total Power Critical Radiant Flux Tester

,

300mm × 450mm Radiant Panel Flooring Radiant Heat Flux Tester

Payment & Shipping Terms
Minimum Order Quantity
1
Price
2255
Packaging Details
Standard Wooden Case
Delivery Time
10 days
Payment Terms
L/C,D/A,D/P,T/T
Supply Ability
15 sets per month
Product Description

YYF001 Critical Radiant Flux Tester ISO9239 Flooring Radiant Heat Flux Test Apparatus
ISO9239 Compliant Critical Radiant Flux Tester with 2KW Total Power and 300mm × 450mm Radiant Panel for Flooring Heat Flux Testing
ISO9239 Compliant Critical Radiant Flux Tester with 2KW Total Power and 300mm × 450mm Radiant Panel for Flooring Heat Flux Testing
ISO9239 Compliant Critical Radiant Flux Tester with 2KW Total Power and 300mm × 450mm Radiant Panel for Flooring Heat Flux Testing

Description:

This test method is used to measure the critical radiant flux of horizontally-mounted floor covering systems exposed to a flaming ignition source in a graded radiant heat environment, within a test chamber. It can also be used to measure this same critical radiant flux for exposed attic floor cellulose insulation. Suitable for all kinds of flooring materials. Such as: textile carpets, soft wood, wood, rubber and plastic flooring and floor boards spray material. The apparatus can be reacted combustion performance flooring including the use of a substrate, backing material, backing material, or flooring materials other changes are likely to affect the test results, which is used to test and describe under controlled conditions in the laboratory, shop combustion characteristics to the material paired heat of reaction to fire.

No. Item Specification
1 Power Supply AC 220V, 50Hz
2 Total Power 2KW
3 Timer Timing accuracy < 1s/h
4 Heat Flux Measurement Range (0–15) kW/m²
5 Heat Flux Meter Accuracy ±0.2 kW/m²
6 Heat Flux Meter Accuracy < ±3%
7 Thermal Radiation Temperature Measurement Range 400–600 ℃, accuracy ±0.5 ℃
8 Blackbody Temperature Error ±5 ℃
9 Exhaust Speed (2.5 ± 0.2) m/s
10 Exhaust Capacity (39–85) m³/min
11 Porous Refractory Radiant Panel Size 300mm × 450mm, approx. 900 ℃ high temperature capability
12 Thermocouple K-type stainless steel sheathed thermocouple, diameter 3.2mm
13 Heat Flux Distribution Requirements At 200mm: (9.1 ± 0.4) kW/m²
At 400mm: (5.0 ± 0.4) kW/m²
At 600mm: (2.4 ± 0.2) kW/m²
14 Combustion Gas Propane (Customer supplied)
15 Combustion Gas Flow Rate (0.026 ± 0.002) L/S
16 Combustion Burner Outer diameter ¢10mm, inner diameter ¢6mm, burner tube with 35 holes of ¢0.7mm
17 Flame Height 60–120mm adjustable
18 Ignition System High-voltage electronic ignition
19 Powerful Exhaust System Equipped with a powerful exhaust fan; the system automatically starts the exhaust fan to exhaust outside after the test is completed
Standard:

GB / T11785 "flooring combustion performance measurement - a radiant heat source”

ISO9239-1: 2002 “flooring combustion performance Part 1-the combustion performance is determined with radiant heat resource”

ASTM E648: Standard Test Method for Critical Radiant Flux of Floor-covering Systems Using a Radiant Heat

ASTM E970: Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source

NFPA 253:Standard Test Method for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source

ISO9239 Compliant Critical Radiant Flux Tester with 2KW Total Power and 300mm × 450mm Radiant Panel for Flooring Heat Flux Testing

Structure:

1. The apparatus is made of combustion chamber and control box;

2. Combustion chamber size: L1420 * W1200 * H2300 (mm);

3. Outline dimension:L2530*W1270*H2700mm(including electric cabinet);

4. Control box / combustion chamber material: high quality (t = 1.2mm) 304 is stainless steel, CNC machining, circular nice shape;

5. Blowtorch: made by our company, 304 stainless steel material, in full compliance with GB / T11785 standards;

6. Other mechanical parts are made of 304 stainless steel or A3 material thicker plating, anti-corrosion and rust.

Send your inquiry directly to us

Privacy Policy China Good Quality Flammability Testing Equipment Supplier. Copyright © 2017-2026 DONGGUAN YUYANG INSTRUMENT CO., LTD . All Rights Reserved.